ALLIANCE HWNLX2SP111CW01 Manual page 89

Table of Contents

Advertisement

Electronic Control Functions
This feature allows the owner to run diagnostic tests
on various washer operations without servicing the
washer. The following tests are available:
• Control Software Version Number
• Service Door Opening Test
• Coin Vault Opening Test
• Coin Drop #1 Input Test
• Coin Drop #2 Input Test
• Lid Switch Input Test
• Pressure Switch Input Tests
• Show Fill Time Test
• Show Drain Time Test
• Start Pulse Test
• Configuration Display Test
• Coin Drop Header Present Test
For an overview of the Manual Diagnostics Test
Feature, refer to the flowchart on the following page.
Test Number
"d001"
"d002"
"d003"
"d004"
"d005"
"d006"
"d007"
"d008"
"d009"
"d010"
"d011"
"d012"
"d013"
202065R6
Testing Machine and
Diagnostic (Testing) Mode – Quick Reference Chart
Diagnostic Mode
Control Software Version # Test
Service Door Opening Test
Coin Vault Opening Test
Coin Drop #1 Input Test
Coin Drop #2 Input Test
Lid Switch Input Test
AC Pressure Switch Test
DC Pressure Switch Test
Show Fill Time Test
Show Drain Time Test
Start Pulse Test
Configuration Display Test
Coin Drop Header Present Test
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
How to Enter Testing Feature
1. Control must be in Ready Mode. If it is not, rapid
advance through a cycle, refer to Rapid Advance
Feature, or if coins or a card has been entered,
refer to Clear Vend Feature.
2. Enter Manual Mode. Refer to Entering the
Manual Mode.
3. Press the DELICATES ( ) or the COLD ( )
keypad until "diAg" appears.
4. Press the START (enter) keypad. Display will
change to "d001" indicating the control software
version number test.
5. Press the DELICATES ( ) or the COLD ( )
keypad to scroll through the diagnostic test
options.
How to Start Tests
To start a diagnostic test, refer to the quick reference
chart below (Table 11). Press the START (enter)
keypad when the desired test number is displayed. For
detailed information on each test, read the appropriate
description.
How to Exit Testing Feature
Press the WARM (<) keypad until the display returns
to the previous mode of operation.
"
S XX"
"
S XX"
"
U XX"
"
C1XX"
"
C2XX"
"
L XX"
"
P XX"
"
P XX"
"
FXXX"
"
dXXX"
"
StXX"
"
AXXX"
"
CHXX"
Table 11
Display
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents