Auto-Flush Mode; Audit Counter Display Mode; Communication Mode; Low Power Mode - ALLIANCE Speed Queen Programming

Frontload washer
Hide thumbs Also See for Speed Queen:
Table of Contents

Advertisement

The control enters this mode when the user presses the
three (3) times in the first three (3) minutes of a cycle. The con-
trol enters Door Unlocking Mode and drains the water. The door
unlocks and the control enters Pause Mode. The display shows
"Cycle Paused" and "You may now open the door". Pressing the
keypad with the door closed resumes the cycle.

Auto-Flush Mode

The control enters Auto-Flush Mode from Ready Mode or Shut-
down Mode on the programmed day and time after the pre-pro-
grammed number of cycles have occurred. The door locks and
the display show "Auto-Flush" and "We apologize for the incon-
venience".
This option is programmable through a network, IR or serial
communication.

Audit Counter Display Mode

This mode provides an alternate method for gaining access to the
audit data in Audit Data Menu. This mode is entered by pressing
the
keypad with the coin vault open and the service door
closed.
To exit, close the coin vault, select BACK, or press the
pad.

Communication Mode

The control enters this mode while IR communication is in pro-
gress. The display shows the IR Communications Menu.

Low Power Mode

This mode is entered from Ready Mode or Shutdown Mode if one
of the four (4) programmable Low Power/Shutdown options be-
comes active when the Low Power option is enabled. To become
active, the current time, day-of-week, date, month, and year must
match the programmed start requirements. Low Power Mode will
automatically exit if the current time, day-of-week, date, month,
and year satisfy an exit condition for the active Low Power/Shut-
down option.
While in Low Power Mode, the display turns off. If a keypad is
pressed, door is opened, coin drop or vend from a serial payment
system or network is detected, the control will wake up from Low
Power Mode for 4.25 minutes. The control resumes its previous
mode. A vend will advance the control to either Partial Vend
Mode or Start Mode as long as Shutdown Mode or Out of Order
Mode is not active. These modes ignore all vends.
If another input is not detected within 4.25 minutes and the con-
trol is in Ready Mode, Shutdown Mode, or Start Mode , the con-
trol will re-enter Low Power Mode and turn off the display. Low
Power Mode can also be entered from Start Mode if Start Mode
was entered with no vend entered, i.e. free vend or OPL.
Note that if the control is in Low Power Mode and a long power
failure occurs, the control will wait 4.25 minutes before re-enter-
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
ing Low Power Mode following Power-up provided that the con-
keypad
trol is in either Ready Mode or Shutdown Mode.

Manual Mode

Manual Mode allows the user to manually program, audit, and
access diagnostic functions rather than requiring the use of IR or
other communication source. When in Manual Mode, the control
displays the System Menu.
The owner can program the control (refer to Globals Menu) to re-
quire users to enter a passcode to access Manual Mode. The pass-
code can only be set with an external device or network.

Rapid Advance Mode

The user can enter Rapid Advance Mode via network or IR de-
vice from Ready Mode, Start Mode or Run Mode.
If enabled (refer to Globals Menu), the user can access Manual
Rapid Advance (refer to Rapid Advance) via the keypad through
the System Menu .
When in Manual Rapid Advance, press the
to the next step.

Manual Diagnostic Mode

key-
Manual Diagnostic Mode allows the user to manually access di-
agnostic functions rather than requiring the use of IR or other
communication source. When in Manual Diagnostic Mode, the
control displays the Diagnostics Menu.

Error Display Mode

If the control detects a machine error, it enters Error Display
Mode and displays the error. Only one (1) error displays at a time
if there are multiple errors. Once the highest priority error is
cleared, the control displays the next highest priority error if mul-
tiple errors exist. See Machine Errors for more details on error
descriptions, error displays and priorities.