Connections

T24-IAe, T24-IAi

Power

Attach power supply wiring to the module as shown below:
Connect to a 3 V power supply or batteries.
This module is not reverse polarity protected!
The maximum voltage is 3.6 V!
For battery information please refer to

Sensor

Voltage input connected as follows:
-Excitation
+5V Excitation

T24-ACM-IA

Power
Power can be supplied by fitting two D cell alkaline 1.5 V batteries or the module can be supplied from an
external 5 Vdc to 18 Vdc source.
In both cases you need to fit the JP1 power jumper to supply power to the transmitter module.
When powered from the external DC source the LED will illuminate.
Mantracourt Electronics Limited
+ 3V Supply
0V Supply
Appendix D – Battery Selection
SHLD
-I
+I
86