T24-ACM-SA

Power

Power can be supplied by fitting two 'D' cell alkaline 1.5 V batteries or the module can be supplied from an
external 5 Vdc to 18 Vdc source.
In both cases you need to fit the JP1 power jumper to supply power to the transmitter module.
When powered from the external DC source the LED will illuminate.
For battery information please refer to

Sensor

The strain gauge input is connected to the module via a 2 part screw terminal block.
Screw Terminal
Function
1
+5 V Excitation
2
+Signal
3
-Signal
4
-Excitation
5
Shield
A
Digital Output
B
Mantracourt Electronics Limited
Pow er Jumper JP1
1
2
3
4
5
A
B
0V
+Supply
LED
Appendix D – Battery Selection
2 X D Cell Batteries
40