Input / Output Configuration

This module does not provide calibration, as such, because it is factory calibrated. However, on this page you can
select the output type and parameters unique to your input sensor.
Items you can change:
Output Type
Pulses per Revolution
Mantracourt Electronics Limited
Simply select the required output type from the drop down list.
Frequency (Hz) – Average frequency of pulses on 'Input A'.
RPM – Average Revolutions Per Minute measured on 'Input A'. If there are
multiple pulses per revolution then set the Pulses Per Revolution setting
accordingly.
Interval (s) – Average time in seconds between pulses measured on 'Input A'.
Counter – Counts incoming pulses on 'Input A'. Count is reset by digital input
to GND or external reset using data provider packet. The edge that increments
the count can be defined by Edge Type and the count will increment by one (1)
at every edge.
Quadrature – Connect both 'Input A' and 'Input B' to the quadrature sensor
and select the appropriate pull up or pull down resistor setting. The count will
be bi-directional and four (4) counts will occur for every quadrature cycle. Use
the Advanced page to set scaling if required.
Digital State – On every change of input state of 'Input A' along with every
Transmit Interval, the current state of 'Input A' will be transmitted. This allows,
with suitable conversion of received value to digital output, wireless
transmission of digital state or button pushes.
Mark (Space) – Gives the percentage of Mark over Space for inputs on 'Input
A'.
Specify the number of pulses per revolution. This parameter only affects the
RPM output value.
140
T24 Telemetry User Manual