All Modes; Indicators; Errors; Other Functions - Mantracourt T24-ACMi-SA User Manual

Telemetry system
Hide thumbs Also See for T24-ACMi-SA:
Table of Contents

Advertisement

All Modes

Indicators

G
NET
SIG LOW
BATT LOW
REMOTE ERROR
REMOTE BATT LOW

Errors

Displayed on handheld LCD.
Error 1
Error 2
Overload
{Display Flashing}

Other Functions

System Zero
Pairing
Mantracourt Electronics Limited
The display is showing Gross weight.
The display is showing Net weight.
The radio signal from the transmitter module is low. The module is still
functioning but the limit of the range may be near. Communications may start
to deteriorate when this indicator is visible. Until ------ is displayed the
communications is still OK and the display can be relied on for accuracy.
Even with a degraded signal the display value will always be
correct.
The batteries in the handheld are low and need to be replaced.
The transmitter module has an error that the handheld does not recognise.
The battery or supply to the transmitter module is low.
The transmitter module has a strain gauge input and is in shunt calibration
mode. An external module has placed the transmitter module in Shunt
Calibration mode so rather than display a misleading reading this error is
displayed instead.
Modules such as the T24-SA support this error type.
Input integrity error. The transmitter module has found a problem with the
input. There may be open or short circuits. Rather than display a misleading
reading this error is displayed instead.
Only certain transmitter modules support this error such as the T24-SA.
The overload limit set by the user has been exceeded.
The motion detection has been enabled and the reading is deemed in motion
or unstable.
If enabled, holding the Tare key for a number of seconds will perform a system
zero.
See Field Transmitter Module Replacement later