Specification; Radio Range - Mantracourt T24-ACMi-SA User Manual

Telemetry system
Hide thumbs Also See for T24-ACMi-SA:
Table of Contents

Advertisement

Specification

Parameter
External Supply voltage
Range + Reverse Polarity
Protection
Maximum Operational
Current
Operating Temperature
Range
Storage Temperature
Range
Humidity
IP Rating

Radio Range

To determine radio range please refer to
Mantracourt Electronics Limited
Minimum
Typical
11
-
0
-
-20
-
0
-
IP65
Appendix B – Antenna Range
Maximum
Units
30
Vdc
3.5
A
50
°C
70
°C
95
%RH
280
Notes
T24 Telemetry User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents