Triggered Reports

Trigger Tab

There are 20 reports that can be pre-defined and triggered by local events or at set intervals. These can deliver
alert/alarm type information or just deliver data to data collection systems etc.
Click on one of the numbered tabs to select a particular report to edit.
NOTE that the changes made while on this page are not saved until you select a different page (not just a
different numbered tab).
Items you can change:
Report Trigger
Mantracourt Electronics Limited
Here you can select the type of trigger for sending the report. Certain triggers
may cause other fields on this page to be disabled.
Selection
0-Disabled
1-Greater Than Limit
2-Less Than Limit
3-Remote Integrity Error
4-Remote Low Battery
Description
This report is disabled
Check the specified channel range against the
specified value and trigger the report if the
channel value exceeds this value
Check the specified channel range against the
specified value and trigger the report if the
channel value is less than this value
Check the specified channels and trigger the
report if any report an integrity error (A
problem with their input)
Check the specified channels and trigger the
report if any report a low battery