T24-PR1

Overview

The T24-PR1 is a thermal printer module that can print a 57 mm wide ticket which can include data from up to 8
modules and optionally sum them. The printout can be triggered from the arrival of data from a specific module
or alternatively by a handheld module which can also optionally supply the data value to print.
Print triggering from an external button/switch option will be made available on future
releases of the T24-PR1.
The actual printed output can be designed by the user using multiple lines which can include free text or tokens
which can represent real data. i.e. <V1> would be decoded as the value from input 1 when the print is triggered
or <TV> would reference the Trigger Value from an external handheld for example.

Order Codes

T24-PR1
The printer module is housed in a non-sealed enclosure.

Connections

Power

You will need to connect a power supply to the T24-PR1 for it to operate and to enable configuration using a
base station and the appropriate toolkit software.
Power is supplied via a 2.5 mm DC plug which plugs into, and locks with, a 2.5 mm socket on the side of the
module. Voltage range is 9 to 36 Vdc and requires approximately a one Ampere (1A) capable supply.
The tip of the connector is positive.