Advanced Settings - Mantracourt T24-ACMi-SA User Manual

Telemetry system
Hide thumbs Also See for T24-ACMi-SA:
Table of Contents

Advertisement

Advanced Settings

This page allows effective conversion between units. i.e. Although all modules supplying data are configured in kg
you can get a printed output in lb.
Items you can change:
Pair Wait Duration
Paired Data Tag
Paired ID
Waker Duration (ms)
Mantracourt Electronics Limited
Here you can set the duration that the T24-AO1 will wait to achieve successful
pairing after the Pair Switch is pressed. The default is 5 seconds.
This shows the currently paired Data Tag. You can click this to manually enter a
Data Tag.
Version 1.1 onwards. This shows the ID of the paired module. This is required if
the analogue output module is to wake the transmitter module when it is first
powered on.
Version 1.1 onwards. To wake the paired transmitter module on power up and to
keep it awake you need to enter a time to try waking the module in milliseconds.
The default is 12000ms (12 seconds).
Enter zero to disable the automatic waking of modules.
The paired transmitter module should have its SleepDelay
parameter set so that once the analogue output module is
turned off the remote module will go back to sleep on its own.
The recommended time for the sleep delay is 10 seconds or
10000ms.
226
T24 Telemetry User Manual