Customer Ticket from Handheld Module

We have a handheld module T24-HA already configured to sum data from 4 modules. We want the F1 button on
the handheld to trigger a printout to a serial printer connected to the T24-SO.
We only want to print the gross sum that the handheld passes us. The handheld is configured to send the Gross
value as Data Tag ABCD when the F1 button is pressed. This is referenced using the <TV> token (Trigger Value).
The printer is not very fast so we can only send a line every 50ms. Also we do not want to print more often than
once every 5 seconds even if the handheld tries to do so. The printer requires a carriage return 0x0D and linefeed
0x0A at the end of each line (So you can use <NL>).
We also want two tickets printed each time it is triggered.
We want the printed output to look like:
ABC Electronics Ltd
Weighment: xx.xxxx kg
Parameter settings:
Line1=ABC Electronics Ltd<NL>
Line2=Weighment: <TV> kg<NL>
SumFormat=00.0000
PrintTrigger=ABCD
LineDelayChar=OD
LineDelay=50
MinInterval=5000
Duplicate=1
Enclosure & Mounting
This module is fitted inside our ACM ABS enclosure. Please see
more information.

Antennas

These modules have the antenna already fitted inside the enclosure so there are no specific mounting
requirements.