Data Rates And Quality - Mantracourt T24-ACMi-SA User Manual

Telemetry system
Hide thumbs Also See for T24-ACMi-SA:
Table of Contents

Advertisement

Data Rates and Quality

This page allows you to select the rate at which data is transmitted from the transmitter module and the quality.
By selecting low power mode and entering some other information the toolkit will also give guides on achievable
battery life.
Note that the battery life calculator is assuming the best case scenario which is at 20°C and that the battery has a
suitable low internal resistance or that a suitable capacitor is fitted across the battery. See battery details in the
Installation section.
Items you can change:
Transmit Interval
Average Sample Period (s)
Mantracourt Electronics Limited
Enter the transmission interval in milliseconds. The default is 1000 giving a
reading every second. You may want increase this value to slow transmissions
down to achieve longer battery life.
The average wind speed as measured over the sample period defined here is
transmitted every Transmit Interval using the Data Tag set in the Advanced
Settings. This period is a moving window so at every transmission interval the
value transmitted will be the average wind speed as measured over the last
sample period up to the transmission event. If the sample period is set to less
than the transmit interval then the value transmitted will actually be the average
of the wind speed since the last transmission. So setting this to zero would
always transmit the average wind speed between transmissions.
150
T24 Telemetry User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents