Message Tab

On the previous Trigger Tab you select whether the report is triggered transitionally or not. If triggered
transitionally you can specify not only the message to send when the trigger test is true but also a message to
send when the trigger test returns to false again.
In the above example you can see that the No Trigger message is disabled because this is not a transitional
triggered report.
Items you can change:
Message On Trigger
Message On No Trigger
Mantracourt Electronics Limited
Enter the report to send when the trigger test returns true. This report can
contain tokens which get decoded to useful information when the report is
transmitted. See
Tokens
For example the message for a report that is triggered on low internal battery
may read:
WARNING: Internal battery low at <v> volts.
On transitionally triggered reports this message is used when the trigger criteria
is no longer met. For example a report triggered on low internal battery would
send this message when the battery voltage is OK. i.e.
Internal battery voltage is OK at <v> volts.