Technical Data; Special Voltages - Fronius TransSynergic 4000 Plasma Operating Instructions Manual

Hide thumbs Also See for TransSynergic 4000 Plasma:
Table of Contents

Advertisement

Available languages

Available languages

Technical data

Special voltages

Technical data
Mains voltage
Mains voltage tolerance
Mains fuse protection (slow-blow)
Primary continuous power (100% d.c.)
Cos phi
Efficiency
Stepless operating current range
Operatingcurrent at
Open-circuit voltage
Working voltage
Protection
Type of cooling
Insulation class
Dimensions (with interface) l / w / h
Weight
Marks of conformity
NOTE! Incorrectly rated mains plugs, mains leads or fuses can cause serious
damage. If the power source is designed for a special voltage, the technical
data on the rating plate applies. The mains plug, mains lead and their fuse
protection must be rated accordingly.
10 min/40°C
10 min/40°C
11
50% d.c.
100% d.c.
3x400 V
+/- 15 %
35 A
12.7 kVA
0,99
88 %
10 – 400 A
400 A
320 A
70 V
up to 48 V
IP 23
AF
F
750 / 310 / 480 mm
35.6 kg
CE