Technical Data; General Remarks; Auto-Transformer Tps 2700, Auto-Transformer Tps 5000; Auto-Transformer Time 5000 - Fronius TPS 2700 Operating Instructions Manual

Autotransformer
Hide thumbs Also See for TPS 2700:
Table of Contents

Advertisement

Available languages

Available languages

Technical data

General remarks

IMPORTANT! If the auto-transformer is designed for special voltages, the technical data
on the rating plate apply. The mains plug, mains lead, and their fuses must be dimensioned
accordingly.
Auto-transformer
TPS 2700, Auto-
transformer TPS
Mains voltage 1 (+/- 10 %)
5000
Mains voltage 2 (+/- 10 %)
Output voltage
Mains fuse protection (slow-blow)
Maximum apparent power
Effective apparent power
Cos phi
Maximum primary current at
mains voltage 1 (500 V)
mains voltage2 (480 V)
Effective primary current at
mains voltage 1 (500 V)
mains voltage2 (480 V)
Secondary current at
10 min / 40 °C 40 % d.c.
10 min / 40 °C 100 % d.c.
Protection
Type of cooling
Insulation class
Dimensions l/w/h
Weight
Marks of conformity
Auto-transformer
TIME 5000
Mains voltage 1 (+/- 10 %)
Mains voltage 2 (+/- 10 %)
Output voltage
Mains fuse protection (slow-blow)
Maximum apparent power
Effective apparent power
Cos phi
56
Auto-transformer
TPS 2700
3 x 500 V
3 x 480 V
3 x 400 V
16 A
9,7 kVA
5,5 kVA
0,9
11 A
12 A
6,5 A
7,0 A
15 A
8 A
IP 23
F
F
640/290/230 mm
25.2/11.42/9.06 in.
23 kg
50.71 Ib.
CE
Auto-transformer
TPS 5000
3 x 500 V
3 x 480 V
3 x 400 V
32 A
27,6 kVA
20,7 kVA
0,9
32 A
34 A
24 A
25 A
40 A
30 A
IP 23
F
F
650/290/230 mm
25.59/11.42/9.06 in.
41 kg
90.39 Ib.
CE,
Auto-transformer
TIME 5000
3 x 500 V
3 x 480 V
3 x 400 V
40 A
33,3 kVA
22,2 kVA
0,9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tps 5000Time 5000