Fault / cause /
Surface of auto-transformer housing feels hot
remedy
Cause:
(continued)
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:

Technical Data

General remarks

Auto-transformer

TC-1000
Mains voltage
Mains voltage tolerance
Power frequency
Mains primary fuse, slow-blow 4 A
Output voltage
Cos phi
Nominal output
Secondary current at
10 min/40 °C; 100 % (d.c.)*
Protection
Type of cooling
Insulation class
Dimensions l/w/h
Weight
Marks of conformity
* duty cycle
permitted duty cycle exceeded
move mains switch to „O" position, allow auto-transformer to cool
input current of the connected Robacta TC-1000 is too high
check the input current of the connected Robacta TC-1000
unsuitable installation location
change installation location (ensure air can move freely through openings
in housing)
ambient temperature too high
reduce ambient temperature or change installation location
housing interior dirty
open auto-transformer and clean with dry compressed air
Note: Inadequately dimensioned electrical installations can lead to serious
damage. The mains supply lead, and its fuse protection, must be dimensioned
accordingly. The technical data shown on the rating plate shall apply.
110V/230V
400V/230V
110 V
400 V
+/- 10 %
+/- 10 %
50/60 Hz
50/60 Hz
2 A
230 V
230 V
0,9
0,9
198 W
284 W
0.8 A
0.8 A
IP 21
IP 21
natural
natural
B
B
470/180/175 mm 470/180/175 mm 470/180/175 mm
18.52/7.1/6.9 in.
18.52/7.1/6.9 in.
5 kg
5 kg
11 lb.
11 lb.
CE/CSA
CE
6
480V/230V
480V
+/- 10 %
50/60 Hz
2 A
230 V
0,9
198 W
0.8 A
IP 21
natural
B
18.52/7.1/6.9 in.
5 kg
11 lb.
CSA