Technical data
Safety
NOTE!
Incorrectly rated mains plugs, mains leads or fuses can result in serious dama-
ge. If the power source is designed for a special voltage, the technical data on
the rating plate apply. Rate the mains plug, mains lead and their fuse protection
accordingly.
Auto-transfor-
Mains voltage 1 (+/- 10 %)
mer MW 2500 /
Mains voltage 2 (+/- 10 %)
3000 -
600/575-460 V
Output voltage
Mains fuse protection (slow-blow)
Maximum apparent power
Effective apparent power
Cos phi
Maximum primary current for
Effective primary current for
Secondary current at
Protection
Type of cooling
Insulation class
Dimensions l x w x h
Weight
Marks of conformity
d.c. = duty cycle
30
Mains voltage 1 (600V)
Mains voltage 2 (575 V)
Mains voltage 1 (600V)
Mains voltage 2 (575 V)
10 min / 40 °C
35 % d.c.
10 min / 40 °C
60 % d.c.
10 min / 40 °C
100 % d.c.
3 x 600 V / 50 / 60 Hz
3 x 575 V / 50 / 60 Hz
3 x 460 V / 440 V
13 A (600V)
13 A (575 V)
12 kVA
9 kVA
0,9
11,6 A
12,2 A
8,7 A
9,1 A
15,1 A
12,4 A
11,4 A
IP 23
ON
B
560 x 250 x 225 mm
22.05 x 9.84 x 8.86 in.
29,4 kg
64.82 lb.
CSA