Item
Step
2
Flatness
Procedure
In the oscilloscope waveform,
(A-B)/A must be less than 0.25. If it
is not, do the following.
1.
Access the SBU as explained in
"Preparation" above.
2.
Set the oscilloscope scale to 0.2
V/unit (vertical) and 0.5 ms/unit
(horizontal).
3.
Connect the oscilloscope probe to
XVIDEO (pin 1 - blue wire) and the
ground to GND (pin 4 - black wire)
on the test lead.
4.
Light the xenon lamp (see page 2-
24).
5.
Remove any test charts that are on
the exposure glass.
6. Loosen the shading plate securing
screws [A].
7. Move the shading plate [B] back
and forth until the waveform meets
the requirements.
8. Tighten the shading plate securing
screws.
3-15