Conditions Used For Flange Strength Calculations - Emerson Rosemount 3308A Reference Manual

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Specifications and Reference Data
August 2017
A.2.9 Conditions used for flange strength calculations
Table A-7. 316 SST or Process Connection with Strength Calculations
Standard Bolting material
ASME
Stainless steel SA193 B8M Class 2
EN, JIS
EN 1515-1/-2 group 13E0, A4-70
Table A-8. Alloy C-276
Standard Bolting material
ASME
UNS N10276
EN, JIS
Table A-9. Duplex 2205
Standard Bolting material
ASME
A193 B7 or A320 L7
®
EN, JIS
Bumax
88
120
PRELIMINARY
Gasket
Soft (1a) with min. thickness
1.6 mm
Soft (EN 1514-1) with min.
thickness 1.6 mm
Gasket
Soft (1a) with min. thickness
1.6 mm
Soft (EN 1514-1) with min.
thickness 1.6 mm
Gasket
Soft (1a) with min. thickness
1.6 mm
Soft (EN 1514-1) with min.
thickness 1.6 mm
00809-0100-4308, Rev CA
Flange material
Stainless steel A182 Gr. F316L
and EN 10222-5-1.4404
Flange material
SB462 Gr. N10276 (solution
annealed condition) or
SB575 Gr. N10276 (solution
annealed condition)
Flange material
Duplex stainless steel
SA/A182 F51 and
EN10222-5-1.4462
or SA/A240 Gr. S31803 and
EN10028-7-1.4462
Specifications and Reference Data
Reference Manual
Hub material
Stainless steel SA479M
316L and
EN 10272-1.4404
Hub material
SB574 Gr. N10276
Hub material
Stainless steel SA479M
S31803 and
EN, JIS Bumax 88 EN
10272-1.4462

Advertisement

Table of Contents
loading

Table of Contents