Emerson Rosemount 3308A Reference Manual page 77

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Reference Manual
00809-0100-4308, Rev CA
7. Secondary Variable
Measurement value of mapped
Second Variable.
10. Percent of Range
Level value in percent of total
measurement range.
Configuration
PRELIMINARY
8. Electronics Temperature
Temperature value of device
electronics.
11. Active Alert Present
This screen will only appear if there
is at least one Active Alert present.
For detailed information of the
failure source and recommended
actions, go to the Active Alerts
screen in AMS Wireless
Configurator or Field
Communicator. Refer to
device status" on page
Some Active Alerts will be displayed
on the LCD display as part of the
diagnostic button screen sequence,
refer to
"Diagnostic button screen
sequence" on page
78.
9. Supply Voltage
Voltage reading of the Power
Module.
> 6 V
5.2 V – 6.0 V
< 5.2 V
"Check
81.
Configuration
August 2017
Good
Low
Very low
65