3.5.3

Coaxial probe

The coaxial probe can be secured to the tank wall by fixtures fastened to the tank wall. Fixtures are
customer supplied. Make sure the probe can move freely due to thermal expansion without getting
stuck in the fixture.
Figure 3-16. Coaxial Probe Secured to the Tank Wall
A. 1.1 in. (28 mm)
The coaxial probe can be guided by a tube welded on the tank bottom. Tubes are customer supplied.
Make sure that the probe can move freely in order to handle thermal expansion. The measurement
accuracy will be reduced close to the tube opening.
Figure 3-17. Coaxial Probe with Tube