Emerson Rosemount 3308A Reference Manual page 190

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Configuration Parameters
August 2017
Near zone compensation
Improves measurement performance in the zone close to the device by compensating for probe
dependent echo signature or recorded echo signature.
If Near Zone Compensation is disabled, neither the probe dependent compensation nor the
compensation due to Trim Near Zone will be used by the device.
Echo search window
Select window mode to use for the echo tracking function. Value typically provided by manufacturer.
Window size
Window size used by echo tracking function. Window Size can only be changed when the Eco Search
Window mode is set to User Defined. Value typically provided by manufacturer.
Gain factor index
Controls the hardware amplification of the waveform. Value typically provided by manufacturer.
Calibration scale factor
Microwave propagation factor to use. Value typically provided by manufacturer.
178
PRELIMINARY
Reference Manual
00809-0100-4308, Rev CA
Configuration Parameters