Emerson Rosemount 3308A Reference Manual page 144

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Specifications and Reference Data
August 2017
Table A-16. Rosemount 3308 Series Spare Parts List - Transmitter Head
Extended product warranty
WR3
3-year limited warranty
WR5
5-year limited warranty
Plantweb diagnostic Functionality
DA1
HART Diagnostics (see
Engineered solutions (see
Pxxx
Engineered Solutions beyond standard model codes. (Consult factory for details)
1.
Not CE approved.
Table A-17. Rosemount 3308 Series Spare Parts List - Probe
Model
Product description
3308A
Guided Wave Radar Level Transmitter
Profile
U
High Performance
S
Standard
Signal output
N
Not Applicable
Measurement type
9
Spare Process Seal and Probe
Housing
N0
Not Applicable
Product certifications
NA
Not Applicable
Operating temperature and pressure (see
S
- 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C)
Material of construction; process connection / probe
1
316L SST (EN 1.4404)
2
Alloy C-276 (UNS N10276). With plate design if flanged version.
3
Alloy 400 (UNS N04400). With plate design if flanged version.
7
PTFE covered probe and flange. With plate design.
8
PTFE covered probe
H
Alloy C-276 (UNS N10276) process connection, flange, and probe
D
Duplex 2205 (UNS S31803) process connection, flange, and probe
132
PRELIMINARY
page
117)
page
123)
page
118)
Reference Manual
00809-0100-4308, Rev CA
Reference accuracy
±0.12 in. (±3 mm)
±0.2 in. (±5 mm)
Probe type
All
3A, 3B, 4A, 4B, and 5A
3A, 3B, 4A, 4B, and 5A
4A and 5A
4A and 5A
3A, 3B, 4A, 4B, and 5A
4B and 5A
Specifications and Reference Data