Canada; Europe; International - Emerson Rosemount 3308A Reference Manual

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Reference Manual
00809-0100-4308, Rev CA
Special Conditions of Certification:
1. The Model 3308 transmitter housing contains aluminum;
protect the enclosure to avoid a potential risk of ignition due
to impact or friction.
2. The surface resistivity of the polymeric antenna is greater
than 1G . To avoid electrostatic charge buildup, it must not
be rubbed or cleaned with solvents or a dry cloth.
3. For use only with the Emerson Process Management Model
701PBKKF SmartPower
Systems, Inc Model MHM-89004 battery module.
4. Only the Emerson Process Management 375 or 475 Field
Communicator is approved for use with this transmitter.
5. The maximum permitted operating temperature of the
Rosemount 3308A transmitter is 70 °C. To avoid the effects
of process temperature and other thermal effects care shall
be taken to ensure that the "Electronics Temperature" does
not exceed 70 °C.
B.6.2 Canada
I6
Canada Intrinsically Safe
Certificate: FM17CA0007X
Standards: CSA Std. C22.2 No. 61010-1:2004, CSA Std. 22.2
No. 94-M91, CAN/CSA-C22.2 NO. 60079-0:15,
CAN/CSA-C22.2 NO. 60079-11:14, C22.2 No.
60529:2016
Markings: INTRINSICALLY SAFE Ex ia
CLASS I, GP A, B, C, D;
CLASS I, Zone 0, Ex ia IIC T4 Ga;
TEMP CODE T4 (-55 °C Ta +70 °C)
Type 4X; IP66; IP67
WHEN INSTALLED PER ROSEMOUNT DRAWING
03308-1010. (See
Special Conditions of Certification:
1. The Model 3308 transmitter housing contains aluminum;
protect the enclosure to avoid a potential risk of ignition due
to impact or friction.
2. The surface resistivity of the polymeric antenna is greater
than 1G . To avoid electrostatic charge buildup, it must not
be rubbed or cleaned with solvents or a dry cloth.
3. For use with the Emerson Process Management 701PBKKF
SmartPower Option or the Computational Systems, Inc
Model MHM-89004 battery module only.
4. Only the Emerson Process Management 375 or 475 Field
Communicator is approved for use with this transmitter.
5. The maximum permitted operating temperature of the
Rosemount 3308A transmitter is 70 °C. To avoid the effects
of process temperature and other thermal effects care shall
be taken to ensure that the "Electronics Temperature" does
not exceed 70 °C.
Product Certifications
PRELIMINARY
Option or the Computational
Figure B-1 on page
151)
B.6.3 Europe
I1
ATEX Intrinsic Safe
Certificate: FM 12ATEX0072X
Standards: EN 60079-0:2012+A11:2013, EN
60079-11:2012; EN 60529:1991+A2:2013
Markings:
Category II 1 G, Ex ia IIC T4 Ga
(-55 °C Ta +70 °C);
1180
2460
Special Conditions of Certification:
1. The Model 3308 transmitter housing contains aluminum;
protect the enclosure to avoid a potential risk of ignition due
to impact or friction.
2. The surface resistivity of the polymeric antenna is greater
than 1G . To avoid electrostatic charge buildup, it must not
be rubbed or cleaned with solvents or a dry cloth.
3. For use only with the ATEX certified (Baseefa11ATEX0042X)
Emerson Process Management Model 701PBKKF
SmartPower Option or the ATEX certified (SIRA
15ATEX2332X) Computational Systems, Inc Model
MHM-89004 battery Module.
4. Only an ATEX certified (BVS03ATEXE347, BVS09ATEXE023)
Emerson Process Management 375 or 475 Field
Communicator is approved for use with this transmitter.
5. The maximum permitted operating temperature of the
Rosemount 3308A transmitter is 70 °C. To avoid the effects
of process temperature and other thermal effects care shall
be taken to ensure that the "Electronics Temperature" does
not exceed 70 °C.
B.6.4 International
I7
IECEx Intrinsic Safety
Certificate: IECEx FMG 12.0029X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga (-55 °C Ta +70 °C)
Special Conditions of Certification:
1. The Model 3308 transmitter housing contains aluminum;
protect the enclosure to avoid a potential risk of ignition due
to impact or friction.
2. The surface resistivity of the polymeric antenna is greater
than 1G . To avoid electrostatic charge buildup, it must not
be rubbed or cleaned with solvents or a dry cloth.
3. For use with only the an IECEx certified (IECEx FMG
12.0029X) Emerson Process Management Model 701PBKKF
SmartPower Option or the IECEx certified (IECEx CSA
15.0045X) Computational Systems, Inc Model MHM-89004
battery pack.
4. Only the Emerson Process Management 375 or 475 Field
Communicator is approved for use with this transmitter.
Product Certifications
August 2017
149

Advertisement

Table of Contents
loading

Table of Contents