Emerson Rosemount 3308A Reference Manual page 97

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Reference Manual
00809-0100-4308, Rev CA
Figure 6-1. Active Alerts Screens
Bandwidth Limited
The device has not yet
received all of the requested
wireless bandwidth needed to
operate as configured. See
"Wireless network
troubleshooting" on page 92
for recommended actions.
Electronics Failure
An electronics error that could
impact the device
measurement reading has
occurred.
Supply Voltage Low
The voltage is below the
recommended operating
range. Replace the Power
Module, see
"Power module
replacement" on page
106.
Service and Troubleshooting
PRELIMINARY
Configuration Warning
The device has detected a
configuration error.
Non-critical operation of the
device may be affected.
Radio Failure
The wireless radio has
detected a failure or stopped
communicating.
Supply Voltage Failure
The supply voltage is too low
and will affect device
operation. Replace the Power
Module, see
"Power module
replacement" on page
106.
Service and Troubleshooting
Configuration Failure
The device has detected a
configuration error. Critical
operation of the device may
be affected.
Sensor Warning
A sensor attached to the
transmitter is degraded.
Readings from that sensor
may not be within accuracy
specifications.
August 2017
Electronics Warning
There is a warning which
should be addressed but
should not affect the device
output.
Sensor Failure
A sensor attached to the
transmitter has failed, and
valid readings from that
sensor are no longer possible.
85

Advertisement

Table of Contents
loading

Table of Contents