Emerson Rosemount 3308A Reference Manual page 39

3308 series wireless guided wave radar
Hide thumbs Also See for Rosemount 3308A:
Table of Contents

Advertisement

Reference Manual
00809-0100-4308, Rev CA
Coaxial probe
1. Mark where to cut the probe.
2. Insert the centering piece.
(The centering piece is delivered from factory and
should be used to prevent the spacers centering
the rod from coming loose).
3. Cut the tube to the desired length.
4. Move the centering piece.
5. Cut the rod inside the tube. Make sure the rod is
fixed with the centering piece while cutting.
Pipes longer than 49 in. (1250 mm) can be
shortened by as much as 23.6 in. (600 mm).
Pipes shorter than 49 in. (1250 mm) can be cut
as long as the remaining length is not less than
15.7 in. (400 mm).
Installation
PRELIMINARY
> 49 in.
(1250 mm)
(1250 mm)
Centering piece
Maximum shortening 23.6
in. (600 mm)
Minimum probe length
15.7 in. (400 mm)
49 in.
Installation
August 2017
27