TG8000 Multiformat Test Signal Generator User Manual
Table 3-22: Timing adjustment ranges for GPS7 output signals (cont.)
Format name
Line settings
1080 23.98sF
± 562
1080 30p
± 562
1080 29.97p
± 562
1080 25p
± 562
1080 24p
± 562
1080 23.98p
± 562
720 60p
± 375
720 59.94p
± 375
720 50p
± 375
BLACK TIMECODE. Use this menu to set timecode parameters for the selected
BLACK output. Press the ENTER button to access the TIMECODE submenu.
(See page 3-127.)
NOTE.
This submenu is available only when a non-HD format is set as the signal
format of the selected BLACK output.
BLANK ON GPS UNLOCK. Use the left (◄) or right (►) arrow button to turn ON
or OFF the blanking function on the BLACK 2 output when a loss of lock to the
GPS/GLONASS signal is detected. When turned on, the BLACK 2 output will be
blanked as long as the loss of lock condition occurs. This purpose of this function
is to trigger a change-over. If configured to blank on loss of lock, this output
should not be used for normal reference applications.
NOTE.
This submenu is available only when BLACK 2 is the selected output.
GPS7 GPS Synchronization and Timecode module
Coarse settings (μs)
± 37.0741
± 29.6296
± 29.6593
± 35.5556
± 37.0370
± 37.0741
± 22.2222
± 22.4444
± 26.6667
Fine settings (ns)
± 7.00
± 7.00
± 7.00
± 7.00
± 7.00
± 7.00
± 7.00
± 7.00
± 7.00
3–125