Availability, mobility, and controller functionality
Configuring Check Point event logging
Before you set up the HiPath Wireless Controller, you must first create OPSEC
>
objects for HiPath Wireless Controller in the Check Point management software. The
name and password you define must also be entered into the HiPath Wireless
Controller Check Point configuration screen.
To enable and configure Check Point:
1.
From the main menu, click Wireless Controller Configuration. The Wireless Controller
Configuration screen appears.
2.
In the left pane, click Check Point. The Check Point Configuration screen appears.
3.
To enable check point logging, select the Enable Check Point Logging checkbox.
4.
Type the following information:
Check Point Server IP – Specifies the IP address of the ELA Management Station
ELA Port – Specifies the port to use for ELA. The default port is 18187.