Siemens SIMATIC NET CP 1612 A2 Operating Instructions Manual

Siemens SIMATIC NET CP 1612 A2 Operating Instructions Manual

Pg/pc - industrial ethernet
Hide thumbs Also See for SIMATIC NET CP 1612 A2:

Advertisement

CP 1612 A2
SIMATIC NET
PG/PC - Industrial Ethernet
CP 1612 A2
Operating Instructions
08/2016
C79000-G8976-C302-02
___________________
Preface
___________________
Description of the device
___________________
Software installation
___________________
Hardware installation
___________________
Configuration
___________________
Technical specifications
___________________
Approvals
1
2
3
4
5
6
A

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET CP 1612 A2

  • Page 1 ___________________ CP 1612 A2 Preface ___________________ Description of the device ___________________ SIMATIC NET Software installation ___________________ Hardware installation PG/PC - Industrial Ethernet CP 1612 A2 ___________________ Configuration ___________________ Technical specifications Operating Instructions ___________________ Approvals 08/2016 C79000-G8976-C302-02...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Preface ..............................5 Description of the device ......................... 9 Software installation ..........................11 Installing the driver ........................11 Uninstalling the driver ......................11 Installing the "SIMATIC NET PC Software" ................11 Uninstalling the "SIMATIC NET PC Software"................ 12 Hardware installation ..........................
  • Page 4 Table of contents CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 5: Preface

    Updated operating instructions on the Internet You will find the current version of these operating instructions on the Product Support pages under the following entry ID: 62611945 (https://support.industry.siemens.com/cs/ww/en/view/62611945) Further documentation The documents listed below contain more detailed information on commissioning and using the communications processor.
  • Page 6 CP 5622 Industry Online Support In addition to the product documentation, the comprehensive online information platform of Siemens Industry Online Support at the following Internet address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc.
  • Page 7 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 8 Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary. You will find the SIMATIC NET glossary on the Internet at the following address: 50305045 (http://support.automation.siemens.com/WW/view/en/50305045) CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 9: Description Of The Device

    Description of the device Product features The CP 1612 A2 is a PCI module for connecting PGs/PCs to Industrial Ethernet. The essential properties are as follows: ● RJ-45 connector for Industrial Ethernet for connecting a twisted-pair cable ● Data rates 10/100/1000 Mbps (half/full duplex) are supported ●...
  • Page 10 Description of the device CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 11: Software Installation

    PC not only the driver for the communications processor. Note Further information on uninstalling When uninstalling STEP 7, note the following instructions (https://support.industry.siemens.com/cs/ww/en/view/189025) Installing the "SIMATIC NET PC Software" "SIMATIC NET PC Software" The "SIMATIC NET PC Software" is the software package with which you can operate the communications processor in your PG/PC.
  • Page 12: Uninstalling The "Simatic Net Pc Software

    Install the software as described in the installation manual "SIMATIC NET PC Software". You will find this installation manual on the Product Support pages under the following entry 77377602 (https://support.industry.siemens.com/cs/ww/en/view/77377602) You should also note the current information on the "SIMATIC NET PC Software" on the Product Support pages in: (https://support.industry.siemens.com/cs/ww/en/ps/15362/pm)
  • Page 13: Hardware Installation

    Notes on passive network components You will find important notes on the use of passive network components in the document "System manual IE/PN passive network components (https://support.industry.siemens.com/cs/ww/en/view/84922825)". Procedure To install and connect up the communications processor follow the steps outlined below:...
  • Page 14 Hardware installation 4.1 Installing and connecting up CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 15: Configuration

    Configuration Configuring To be able to configure the communications processor, the following engineering or configuration tools are available: ● STEP 7 V5.5 ● STEP 7 Professional (TIA Portal) ● Communication Settings (COML S7) The steps involved are described in the "Commissioning PC Stations" manual or in the relevant online helps.
  • Page 16 Configuration CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 17: Technical Specifications

    Technical specifications CP 1612 A2 The following technical specifications apply to the CP 1612 A2 communications processor: Data transfer Transmission speed 10/100 /1000 Mbps Interfaces Connection to 10BaseT/100BaseTX/1000BaseT RJ-45 connector Connection to PC/PG PCI slot (3.3 V/5 V, 32 bits) Voltage Power supply +5 V, +/-5 %;...
  • Page 18 Technical specifications CP 1612 A2 Operating Instructions, 08/2016, C79000-G8976-C302-02...
  • Page 19: Approvals

    Declaration of conformity You will find the declaration of conformity for this communications processor on the Product Support pages under the following entry ID: 58826997 (https://support.industry.siemens.com/cs/ww/en/view/58826997) C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard according to EN 61000-6-3.
  • Page 20 ● Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.

This manual is also suitable for:

6gk1161-2aa01

Table of Contents