Configuring The Information Center - Huawei Quidway S3700 Series Configuration Manual

V100r006c00
Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Device Management
Table 6-4 Description of each field in the format of alarms
Field
TimeStamp
HostName
ModuleName
Severity
Brief
Description

6.2 Configuring the Information Center

This section describes how to manage and configure the information center.
Issue 01 (2011-07-15)
Indication
Time to send out the
information
Host name
Module name
Severity of
information
Brief information
Description
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 Monitoring the Device Through the Information Center
Description
Five timestamp formats are available:
l boot: indicates relative time. By default,
debugging information adopts this timestamp
format.
l date: indicates the timestamp in the format of
system time. By default, logs and traps adopt
this timestamp format.
l short-date: indicates system time. The short-
date format does not contain year information.
l format-date: indicates another format of system
time.
l none: indicates that no timestamp is contained
in traps.
The timestamp and the host name are separated by
a blank space.
By default, the name is Quidway.
There is a space between the sysname and module
name.
Indicates the name of the module that generates an
alarm.
Indicates the severity of alarms:
l Critical
l Major
l Minor
l Warning
l Indeterminate
l Cleared
Provides brief information of the alarms.
Provides a detailed description of the alarms.
54