Configuration Roadmap
The configuration roadmap is as follows:
1.
2.
3.
Data Preparation
To complete the configuration, you need the following data:
l
l
Procedure
Step 1 Configure input lines on the Switch.
# Enable the monitoring function on input lines 1 to 4.
<Quidway> system-view
[Quidway] monitor input 1 enable
[Quidway] monitor input 2 enable
[Quidway] monitor input 3 enable
[Quidway] monitor input 4 enable
# Set the names and normal levels of the input lines.
[Quidway] monitor input 1 name input1 normal-state high-level
[Quidway] monitor input 2 name input2 normal-state high-level
[Quidway] monitor input 3 name input3 normal-state high-level
[Quidway] monitor input 4 name input4 normal-state high-level
Step 2 Configure output lines on the Switch.
# Configure the association between output line 1 and input line 1 and set the lines in the normal
state to be of high level.
[Quidway] monitor output 1
[Quidway-monitor-output1] rule 1 match-input 1000 key 1000
[Quidway-monitor-output1] quit
# Configure the association between output line 2 and input line 2 and set the lines in the normal
state to be of high level.
[Quidway] monitor output 2
[Quidway-monitor-output2] rule 1 match-input 0100 key 0100
[Quidway-monitor-output2] quit
# Configure the association between output line 3 and input lines 3 and 4, and then set the lines
in the normal state to be of high level.
[Quidway] monitor output 3
[Quidway-monitor-output3] rule 1 match-input 0010 key 0010
[Quidway-monitor-output3] rule 2 match-input 0001 key 0001
[Quidway-monitor-output3] quit
Step 3 Verify the configuration.
# Verify that the configuration takes effect through audible and visual trap devices.
Issue 01 (2011-07-15)
Configure input lines.
Configure output lines.
Configure the logical relationships between input lines and output lines.
Names of input lines
Normal levels of the input lines, that is, input lines 1 to 4 being of high level in the normal
state
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Configuring a Monitoring Interface