Configuring An Input Line Connected To A Monitoring Interface; Checking The Configuration - Huawei Quidway S3700 Series Configuration Manual

V100r006c00
Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Device Management
No.
1
2
7.2.2 Configuring an Input Line Connected to a Monitoring
Interface
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
monitor input id-number enable
The monitoring function is enabled on an input line.
Step 3 Run:
monitor input id-number name line-name normal-state { low-level | high-level }
The name and the normal level of a monitored input line are set.
----End

7.2.3 Checking the Configuration

Prerequisite
All configurations of the input lines connected to a specified monitoring interface are complete.
Procedure
l
----End
Example
Run the display monitor input all command. If you can view information about all input lines
connected to the monitoring interface, it means that the configuration succeeds. For example:
<Quidway> display monitor input all
---------------------------------------------------------------------------
LineID
---------------------------------------------------------------------------
1
2
3
4
---------------------------------------------------------------------------
Issue 01 (2011-07-15)
Data
Normal levels of input lines 1 to 4 connected to a monitoring interface
Names of input lines
Run the display monitor input { id-number | all } command to check the previous
configuration.
LineName
Inputline1
Inputline2
Inputline3
Inputline4
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Enable
NormalStatus
enable
low-level
enable
high-level
enable
high-level
enable
low-level
7 Configuring a Monitoring Interface
CurrentStatus
abnormal
normal
normal
normal
66

Advertisement

Table of Contents
loading

Table of Contents