Configuring An Output Line; Checking The Configuration - Huawei Quidway S3700 Series Configuration Manual

V100r006c00
Hide thumbs Also See for Quidway S3700 Series:
Table of Contents

Advertisement

Quidway S3700 Series Ethernet Switches
Configuration Guide - Device Management
The system view is displayed.
Step 2 Run:
monitor input id-number enable
The monitoring function is enabled on an input line.
Step 3 Run:
monitor input id-number name line-name normal-state { low-level | high-level }
The name and the normal level of a monitored input line are configured.
----End

7.3.3 Configuring an Output Line

Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
monitor output id-number
An output control list is created for an output line and the output view is displayed.
Step 3 Run:
rule rule-id match-input line-mask key level-value
The input interface monitored by the output interface is configured and the logical relationship
between the two interfaces is set up.
----End

7.3.4 Checking the Configuration

Prerequisite
All configurations of the input lines and output lines connected to a specified monitoring
interface are complete.
Procedure
l
----End
Example
Run the display monitor output 1 command. If you can view the matching rule of the output
line of a specified monitoring interface, it means that the configuration succeeds. For example:
<Quidway> display monitor output 1
----------------------------------------------------------------------------------
----------------
RuleID
Issue 01 (2011-07-15)
Run the display monitor output id-number command to check the previous configuration.
InputMask
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
LevelValue
7 Configuring a Monitoring Interface
68