Obtaining Valid Ip Addresses For The End-User's Pc; Testing The Data Link - WaveRider LMS4000 User Manual

900 mhz radio network
Table of Contents

Advertisement

9 Installing the EUM

9.4.9 Obtaining Valid IP Addresses for the End-user's PC

1. To obtain IP addresses for the end-user's PC, including the PC IP address, Gateway
IP address, and DNS server address, the PC must request an update from the DHCP
server. This procedure varies depending on which version of Windows operating
system is running on the end-user's PC, but a general method is outlined as follows:
For Windows 95, 98:
2. If no error messages are returned, the WISP network has successfully provided an IP
address to the end-user's PC. You can confirm the success by checking the assigned
IP addresses. If the assigned Gateway IP address corresponds to the EUM Gateway
IP address, then the operation was successful.
3. If a valid IP address cannot be achieved, see

9.4.10 Testing the Data Link

The fact that the IP address was successfully obtained indicates that the data link from the PC
to the WISP's network is functioning properly. WaveRider recommends more thorough testing
of the EUM-to-CCU data link, as outlined below. These tests can also be used to troubleshoot
simple problems if DHCP access is not available.
There are several tools available for testing the quality of the link between the end-user PC
and the WISP network. The most important tool is the ping utility, which is available in the
CCU, EUM, and the end-user PC. The ping command can be used to progressively test the
data link, as follows:
To Test the Data Link from the End-user's PC to the
Testing the Data Link from the End-user's PC to the
Testing the Data Link from the End-user's PC to the
To Test the Data Link from the End-user's PC to the EUM
1. Ping the EUM's IP address from the end-user's PC, as follows:
2. If there is no response, check the following:
3. If there is a response, but with errors, check the Ethernet crossover cable.
116
Using Windows utility winipcfg, select Start > Run, type <winipcfg> in
the command line, and press Enter.
From the winipcfg menu, select Release All, then Renew All.
Using DOS, select Start > Run, type cmd or command (the exact process
may vary, so consult your operating system manual)
Using the <ipconfig> command set, Renew all adaptors.
Open a DOS window in the end-user's PC.
At the command prompt, type ping <aaa.bbb.ccc.ddd>, where
<aaa.bbb.ccc.ddd> is the IP address of the EUM and press Enter.
PC IP address settings.
Ethernet crossover cable between the EUM and the end-user's PC, to ensure
that the pins have not been damaged and that the pin-outs are consistent with
those shown in
General Troubleshooting
Troubleshooting
on page 121.
EUM, on page 116
Network, on page 118
Internet, on page 119
Information, on page 151.
APCD-LM043-4.0

Advertisement

Table of Contents
loading

Table of Contents