Chapter 2: System hardware
One LPU and grounding kit
the ODU is to be connected to an auxiliary device, one additional LPU and grounding kit is
required for the Aux drop cable. Order the kits from Cambium Networks
Table 21 LPU and grounding kit part number
Cambium description
PTP 650 LPU and Grounding Kit
Note
PTP 650 LPUs are not suitable for installation on SFP copper Cat5e Ethernet interfaces.
For SFP drop cables, obtain suitable surge protectors from a specialist supplier.
SFP optical Ethernet interfaces do not require surge protectors.

RJ45 connectors and spare glands

RJ45 connectors are required for plugging Cat5e cables into ODUs, LPUs, PSUs and other devices.
Order RJ45 connectors and crimp tool from Cambium Networks
Note
The RJ45 connectors and crimp tool listed in
BBDGe cable (as supplied by Cambium Networks). They may not work with other
types of cable.
The ODU is supplied with one environmental sealing gland for the drop cable. However, this is not
suitable when surge protection is required: EMC glands must be used instead. EMC strain relief
cable glands (quantity 5) are included in the LPU and grounding kit
with a black sealing nut. If extra glands are required, order them from Cambium Networks (in
packs of 10)
(Table
22).
One long EMC strain relief gland
the standard cable gland as it must house an SFP module plugged into the ODU.
Figure 17 Cable gland
(Table
20) is required for the PSU drop cable connection to the ODU. If
(Figure
21) is included in each SFP module kit. This is longer than
Page
2-24
(Table
21).
Cambium part number
C000065L007
(Table
22).
Table 22
work with Superior Essex type
(Figure
17). These are identified