Email Alerts - Cambium Networks PTP 650 Series User Manual

Table of Contents

Advertisement

Chapter 7: Operation
Alarm
Syslog Local Wrapped
Aux Port Configuration Mismatch
Syslog Client Enabled/Disabled
Warning
Ethernet Bridging Status
Remaining Full Capacity Time
Trial
Capacity Variant Mismatch

Email alerts

The management agent can be configured to generate alerts by electronic mail when certain
events occur. The alerts are defined in
Table 102 Email alerts
Alert
Wireless Link Up Down
Channel Change
DFS Impulse Interference
Enabled Diagnostic Alarms
Main PSU Port Up Down
Aux Port Up Down
SFP Port Up Down
Meaning
The local log of event messages is full and is now being
overwritten by new messages.
Ethernet fragments (runt packets) have been detected
when the Aux port is in full duplex. This indicates an auto-
negotiation or forced configuration mismatch.
The local syslog client has been enabled or disabled.
"
" means that the link has stopped bridging
Disabled
Ethernet frames because the Lowest Ethernet Modulation
Mode is not being achieved or because the wireless link is
down.
Time remaining on the full capability trial period. Activated
when seven days or less of the trial period remain.
The link ends are different capability variants, for example,
one is Full and the other is Med.
Table
102.
Meaning
There has been a change in the status of the wireless link.
DFS has forced a change of channel.
DFS has detected impulse interference.
Diagnostic alarms have been enabled.
There has been a change in the status of the PSU data port.
There has been a change in the status of the Aux port.
There has been a change in the status of the SFP port.
Page
7-15
Alarms, alerts and messages

Advertisement

Table of Contents
loading