GE G60 Instruction Manual page 422

Ur series generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
F224
ENUMERATION: RATE TREND FOR FREQ RATE OF CHANGE
0 = Increasing, 1 = Decreasing, 2 = Bidirectional
F225
ENUMERATION: SPLIT PHASE PROTECTION MODE
B
0 = Over, 1 = Over-Under
F226
ENUMERATION: REMOTE INPUT/OUTPUT TRANSFER
METHOD
0 = None, 1 = GSSE, 2 = GOOSE
F227
ENUMERATION: RELAY SERVICE STATUS
0 = Unknown, 1 = Relay In Service, 2 = Relay Out Of Service
F230
ENUMERATION: DIRECTIONAL POLARIZING
0 = Voltage, 1 = Current, 2 = Dual
F231
ENUMERATION: POLARIZING VOLTAGE
0 = Calculated V0, 1 = Measured VX
F232
ENUMERATION: CONFIGURABLE GOOSE DATASET ITEMS
FOR TRANSMISSION
value
GOOSE dataset item
0
None
1
GGIO1.ST.Ind1.q
2
GGIO1.ST.Ind1.stVal
3
GGIO1.ST.Ind2.q
4
GGIO1.ST.Ind2.stVal
255
GGIO1.ST.Ind128.q
256
GGIO1.ST.Ind128.stVal
257
MMXU1.MX.TotW.mag.f
258
MMXU1.MX.TotVAr.mag.f
259
MMXU1.MX.TotVA.mag.f
260
MMXU1.MX.TotPF.mag.f
261
MMXU1.MX.Hz.mag.f
262
MMXU1.MX.PPV.phsAB.cVal.mag.f
263
MMXU1.MX.PPV.phsAB.cVal.ang.f
264
MMXU1.MX.PPV.phsBC.cVal.mag.f
265
MMXU1.MX.PPV.phsBC.cVal.ang.f
266
MMXU1.MX.PPV.phsCA.cVal.mag.f
267
MMXU1.MX.PPV.phsCA.cVal.ang.f
268
MMXU1.MX.PhV.phsA.cVal.mag.f
B-64
G60 Generator Management Relay
value
GOOSE dataset item
269
MMXU1.MX.PhV.phsA.cVal.ang.f
270
MMXU1.MX.PhV.phsB.cVal.mag.f
271
MMXU1.MX.PhV.phsB.cVal.ang.f
272
MMXU1.MX.PhV.phsC.cVal.mag.f
273
MMXU1.MX.PhV.phsC.cVal.ang.f
274
MMXU1.MX.A.phsA.cVal.mag.f
275
MMXU1.MX.A.phsA.cVal.ang.f
276
MMXU1.MX.A.phsB.cVal.mag.f
277
MMXU1.MX.A.phsB.cVal.ang.f
278
MMXU1.MX.A.phsC.cVal.mag.f
279
MMXU1.MX.A.phsC.cVal.ang.f
280
MMXU1.MX.A.neut.cVal.mag.f
281
MMXU1.MX.A.neut.cVal.ang.f
282
MMXU1.MX.W.phsA.cVal.mag.f
283
MMXU1.MX.W.phsB.cVal.mag.f
284
MMXU1.MX.W.phsC.cVal.mag.f
285
MMXU1.MX.VAr.phsA.cVal.mag.f
286
MMXU1.MX.VAr.phsB.cVal.mag.f
287
MMXU1.MX.VAr.phsC.cVal.mag.f
288
MMXU1.MX.VA.phsA.cVal.mag.f
289
MMXU1.MX.VA.phsB.cVal.mag.f
290
MMXU1.MX.VA.phsC.cVal.mag.f
291
MMXU1.MX.PF.phsA.cVal.mag.f
292
MMXU1.MX.PF.phsB.cVal.mag.f
293
MMXU1.MX.PF.phsC.cVal.mag.f
294
MMXU2.MX.TotW.mag.f
295
MMXU2.MX.TotVAr.mag.f
296
MMXU2.MX.TotVA.mag.f
297
MMXU2.MX.TotPF.mag.f
298
MMXU2.MX.Hz.mag.f
299
MMXU2.MX.PPV.phsAB.cVal.mag.f
300
MMXU2.MX.PPV.phsAB.cVal.ang.f
301
MMXU2.MX.PPV.phsBC.cVal.mag.f
302
MMXU2.MX.PPV.phsBC.cVal.ang.f
303
MMXU2.MX.PPV.phsCA.cVal.mag.f
304
MMXU2.MX.PPV.phsCA.cVal.ang.f
305
MMXU2.MX.PhV.phsA.cVal.mag.f
306
MMXU2.MX.PhV.phsA.cVal.ang.f
307
MMXU2.MX.PhV.phsB.cVal.mag.f
308
MMXU2.MX.PhV.phsB.cVal.ang.f
309
MMXU2.MX.PhV.phsC.cVal.mag.f
310
MMXU2.MX.PhV.phsC.cVal.ang.f
311
MMXU2.MX.A.phsA.cVal.mag.f
312
MMXU2.MX.A.phsA.cVal.ang.f
313
MMXU2.MX.A.phsB.cVal.mag.f
314
MMXU2.MX.A.phsB.cVal.ang.f
315
MMXU2.MX.A.phsC.cVal.mag.f
316
MMXU2.MX.A.phsC.cVal.ang.f
317
MMXU2.MX.A.neut.cVal.mag.f
318
MMXU2.MX.A.neut.cVal.ang.f
319
MMXU2.MX.W.phsA.cVal.mag.f
320
MMXU2.MX.W.phsB.cVal.mag.f
321
MMXU2.MX.W.phsC.cVal.mag.f
APPENDIX B
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents