B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 47)
ADDR
REGISTER NAME
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (16 items)
2F80
Remote Input States, one per register (64 items)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
B
3001
Oscillography Available Records
3002
Oscillography Last Cleared Date
3004
Oscillography Number Of Cycles Per Record
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
3011
Oscillography Clear Data
User Programmable Fault Report Commands (Read/Write Command)
3060
User Fault Report Clear
User Programmable Fault Report Actuals (Read Only)
3070
Newest Record Number
3071
Cleared Date
3073
Report Date (10 items)
User Programmable Fault Report (Read/Write Setting) (2 modules)
3090
Fault Report 1 Fault Trigger
3091
Fault Report 1 Function
3092
Fault Report 1 Prefault Trigger
3093
Fault Report Analog Channel 1 (32 items)
30B3
Fault Report 1 Reserved (5 items)
30B8
...Repeated for Fault Report 2
Modbus file transfer (read/write)
3100
Name of file to read
Modbus file transfer values (read only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Event recorder actual values (read only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event recorder commands (read/write)
3406
Event Recorder Clear Command
DCMA Input Values (Read Only) (24 modules)
34C0
DCMA Inputs 1 Value
34C2
DCMA Inputs 2 Value
34C4
DCMA Inputs 3 Value
34C6
DCMA Inputs 4 Value
34C8
DCMA Inputs 5 Value
34CA
DCMA Inputs 6 Value
34CC
DCMA Inputs 7 Value
34CE
DCMA Inputs 8 Value
34D0
DCMA Inputs 9 Value
34D2
DCMA Inputs 10 Value
34D4
DCMA Inputs 11 Value
34D6
DCMA Inputs 12 Value
34D8
DCMA Inputs 13 Value
34DA
DCMA Inputs 14 Value
34DC
DCMA Inputs 15 Value
34DE
DCMA Inputs 16 Value
34E0
DCMA Inputs 17 Value
B-14
RANGE
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 400000000
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 65535
0 to 1
0 to 65535
0 to 65536
---
---
0 to 4294967295
0 to 65535
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
-9999999 to 9999999
G60 Generator Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F155
---
1
F108
---
1
F001
---
1
F001
---
1
F050
---
1
F001
---
1
F126
---
1
F126
---
1
F126
---
1
F001
---
1
F050
---
1
F050
---
1
F300
---
1
F102
---
1
F300
---
1
F600
---
---
F001
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
---
1
F004
DEFAULT
0 (Offline)
0 (Off)
0
0
0
0
0 (No)
0 (No)
0 (No)
0
0
0
0
0 (Disabled)
0
0
0
(none)
0
0
0
0
0
0
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
GE Multilin