GE G60 Instruction Manual page 400

Ur series generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 35 of 47)
ADDR
REGISTER NAME
B275
IEC 61850 GGIO2.CF.SPCSO54.ctlModel Value
B276
IEC 61850 GGIO2.CF.SPCSO55.ctlModel Value
B277
IEC 61850 GGIO2.CF.SPCSO56.ctlModel Value
B278
IEC 61850 GGIO2.CF.SPCSO57.ctlModel Value
B279
IEC 61850 GGIO2.CF.SPCSO58.ctlModel Value
B
B27A
IEC 61850 GGIO2.CF.SPCSO59.ctlModel Value
B27B
IEC 61850 GGIO2.CF.SPCSO60.ctlModel Value
B27C
IEC 61850 GGIO2.CF.SPCSO61.ctlModel Value
B27D
IEC 61850 GGIO2.CF.SPCSO62.ctlModel Value
B27E
IEC 61850 GGIO2.CF.SPCSO63.ctlModel Value
IEC 61850 Report Settings (Read/Write Setting) (14 modules)
B280
IEC 61850 Report Control 1 RptID
B2A1
IEC 61850 Report Control 1 OptFlds
B2A2
IEC 61850 Report Control 1 BufTm
B2A4
IEC 61850 Report Control 1 TrgOps
B2A5
IEC 61850 Report Control 1 IntgPd
B2A7
...Repeated for Report 2
B2CE
...Repeated for Report 3
B2F5
...Repeated for Report 4
B31C
...Repeated for Report 5
B343
...Repeated for Report 6
B36A
...Repeated for Report 7
B391
...Repeated for Report 8
B3B8
...Repeated for Report 9
B3DF
...Repeated for Report 10
B406
...Repeated for Report 11
B42D
...Repeated for Report 12
B454
...Repeated for Report 13
B47B
...Repeated for Report 14
B4A2
...Repeated for Report 15
B4C9
...Repeated for Report 16
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
B500
Number of Status Indications in GGIO1
B501
IEC 61850 GGIO1 Indication operands (128 items)
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function
B5A1
IEC 61850 Configurable GOOSE ID
B5C2
Configurable GOOSE Destination MAC Address
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
B5C6
IEC 61850 Configurable GOOSE VLAN ID
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
B5C8
IEC 61850 Configurable GOOSE ConfRev
B5CA
Configurable GOOSE Dataset Items for Transmission
B60A
...Repeated for Module 2
B674
...Repeated for Module 3
B6DE
...Repeated for Module 4
B748
...Repeated for Module 5
B7B2
...Repeated for Module 6
B81C
...Repeated for Module 7
B886
...Repeated for Module 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (8 modules)
B900
Configurable GOOSE Dataset Items for Transmission
B940
...Repeated for Module 2
B980
...Repeated for Module 3
B-42
RANGE
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
---
0 to 65535
0 to 4294967295
0 to 65535
0 to 4294967295
8 to 128
---
0 to 1
---
---
0 to 7
0 to 4095
0 to 16383
1 to 4294967295
0 to 256
0 to 128
G60 Generator Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
---
F209
---
1
F001
---
1
F003
---
1
F001
---
1
F003
---
8
F001
---
1
F300
---
1
F102
---
---
F209
"GOOSEOut_x_"
---
---
F072
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F232
---
1
F233
DEFAULT
2
2
2
2
2
2
2
2
2
2
0
0
0
0
8
0
0 (None)
0
4
0
0
1
0 (None)
0 (None)
GE Multilin