GE G60 Instruction Manual page 371

Ur series generator management relay
Hide thumbs Also See for G60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 6 of 47)
ADDR
REGISTER NAME
1C0C
Source 1 Phase B Reactive Power
1C0E
Source 1 Phase C Reactive Power
1C10
Source 1 Three Phase Apparent Power
1C12
Source 1 Phase A Apparent Power
1C14
Source 1 Phase B Apparent Power
1C16
Source 1 Phase C Apparent Power
1C18
Source 1 Three Phase Power Factor
1C19
Source 1 Phase A Power Factor
1C1A
Source 1 Phase B Power Factor
1C1B
Source 1 Phase C Power Factor
1C1C
Reserved (4 items)
1C20
...Repeated for Source 2
1C40
...Repeated for Source 3
1C60
...Repeated for Source 4
1C80
...Repeated for Source 5
1CA0
...Repeated for Source 6
Source Energy (Read Only Non-Volatile) (6 modules)
1D00
Source 1 Positive Watthour
1D02
Source 1 Negative Watthour
1D04
Source 1 Positive Varhour
1D06
Source 1 Negative Varhour
1D08
Reserved (8 items)
1D10
...Repeated for Source 2
1D20
...Repeated for Source 3
1D30
...Repeated for Source 4
1D40
...Repeated for Source 5
1D50
...Repeated for Source 6
Energy Commands (Read/Write Command)
1D60
Energy Clear Command
Source Frequency (Read Only) (6 modules)
1D80
Frequency for Source 1
1D82
Frequency for Source 2
1D84
Frequency for Source 3
1D86
Frequency for Source 4
1D88
Frequency for Source 5
1D8A
Frequency for Source 6
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Synchrocheck Actuals (Read Only) (2 modules)
2400
Synchrocheck 1 Delta Voltage
2402
Synchrocheck 1 Delta Frequency
2403
Synchrocheck 1 Delta Phase
2404
...Repeated for Synchrocheck 2
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
Expanded Digital Input/Output states (Read Only)
2D00
Contact Input States, one per register (96 items)
2D80
Contact Output States, one per register (64 items)
2E00
Virtual Output States, one per register (96 items)
GE Multilin
RANGE
-1000000000000 to
1000000000000
-1000000000000 to
1000000000000
-1000000000000 to
1000000000000
-1000000000000 to
1000000000000
-1000000000000 to
1000000000000
-1000000000000 to
1000000000000
-0.999 to 1
-0.999 to 1
-0.999 to 1
-0.999 to 1
---
0 to 1000000000000
0 to 1000000000000
0 to 1000000000000
0 to 1000000000000
---
0 to 1
---
---
---
---
---
---
0 to 1
-1000000000000 to
1000000000000
0 to 655.35
0 to 179.9
0 to 1
0 to 1
0 to 1
0 to 1
G60 Generator Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
var
0.001
F060
var
0.001
F060
VA
0.001
F060
VA
0.001
F060
VA
0.001
F060
VA
0.001
F060
---
0.001
F013
---
0.001
F013
---
0.001
F013
---
0.001
F013
---
---
F001
Wh
0.001
F060
Wh
0.001
F060
varh
0.001
F060
varh
0.001
F060
---
---
F001
---
1
F126
Hz
---
F003
Hz
---
F003
Hz
---
F003
Hz
---
F003
Hz
---
F003
Hz
---
F003
---
1
F126
V
1
F060
Hz
0.01
F001
degrees
0.1
F001
---
1
F108
---
1
F108
---
1
F108
---
1
F108
DEFAULT
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (No)
0
0
0
0
0
0
0 (No)
0
0
0
0 (Off)
0 (Off)
0 (Off)
0 (Off)
B-13