APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 20 of 47)
ADDR
REGISTER NAME
6743
Generator Unbalance Stage 1 Pickup
6744
Generator Unbalance Stage 1 K value
6745
Generator Unbalance Stage 1 Tmin
6746
Generator Unbalance Stage 1 Tmax
6747
Generator Unbalance Stage 1 K Reset
6748
Generator Unbalance Stage 2 Pickup
6749
Generator Unbalance Stage 2 Pickup Delay
674A
Generator Unbalance Block
674B
Generator Unbalance Target
674C
Generator Unbalance Events
674D
Reserved (3 items)
Stator Ground Source (Read/Write Grouped Setting)
6750
Stator Ground Source
Stator Ground (Read/Write Grouped Setting)
6780
Stator Ground Function
6781
Stator Ground Stage 1 Pickup
6782
Stator Ground Stage 1 Pickup Delay
6783
Stator Ground Stage 1 Supervision
6784
Stator Ground Stage 2 Pickup
6785
Stator Ground Stage 2 Pickup Delay
6786
Stator Ground Stage 2 Supervision
6787
Stator Ground Block
6788
Stator Ground Target
6789
Stator Ground Event
678A
Reserved (5 items)
Split Phase Protection (Read/Write Grouped Setting)
67A0
Split Phase Protection Function
67A1
Split Phase Protection Source
67A2
Split Phase Protection Load Source
67A3
Split Phase Protection Phase A Pickup
67A4
Split Phase Protection Phase A Offset
67A5
Split Phase Protection Phase A Slope
67A6
Split Phase Protection Phase B Pickup
67A7
Split Phase Protection Phase B Offset
67A8
Split Phase Protection Phase B Slope
67A9
Split Phase Protection Phase C Pickup
67AA
Split Phase Protection Phase C Offset
67AB
Split Phase Protection Phase C Slope
67AC
Split Phase Protection Minimum Load
67AD
Split Phase Protection Mode
67AE
Split Phase Protection Delay
67AF
Split Phase Protection Block
67B0
Split Phase Protection Target
67B1
Split Phase Protection Events
67B2
Reserved (6 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase Undervoltage 1 Function
7001
Phase Undervoltage 1 Signal Source
7002
Phase Undervoltage 1 Pickup
7003
Phase Undervoltage 1 Curve
7004
Phase Undervoltage 1 Delay
7005
Phase Undervoltage 1 Minimum Voltage
7006
Phase Undervoltage 1 Block
7007
Phase Undervoltage 1 Target
GE Multilin
RANGE
0 to 100
0 to 100
0 to 50
0 to 1000
0 to 1000
0 to 100
0 to 1000
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 5
0 to 1
0 to 0.25
0 to 600
0.001 to 0.1
0 to 0.25
0 to 600
0.001 to 0.1
---
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 5
0.020 to 1.500
0 to 1
0 to 100
0.020 to 1.500
0 to 1
0 to 100
0.020 to 1.500
0 to 1
0 to 100
0 to 1
0 to 1
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
0 to 2
G60 Generator Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
%
0.01
F001
---
0.01
F001
s
0.001
F001
s
0.1
F001
s
0.1
F001
%
0.01
F001
s
0.1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
---
1
F102
pu
0.001
F001
s
0.01
F001
pu
0.0001
F001
pu
0.001
F001
s
0.01
F001
pu
0.0001
F001
---
---
F001
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F167
pu
0.001
F001
pu
0.001
F001
%
0.1
F001
pu
0.001
F001
pu
0.001
F001
%
0.1
F001
pu
0.001
F001
pu
0.001
F001
%
0.1
F001
pu
0.01
F001
---
1
F225
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
DEFAULT
800
100
250
6000
2400
B
300
50
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
0 (Disabled)
150
100
57
150
0
45
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC1)
0 (SRC1)
200
0
0
200
0
0
200
0
0
0
0 (Over)
0
0
0 (Self-Reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0
0 (Self-reset)
B-27