System Fan Replacement; To Remove A Failed System Fan; To Install A New System Fan; Figure 125. System Fan Removal - Intel R2000WF series Service Manual

Hide thumbs Also See for R2000WF series:
Table of Contents

Advertisement

Intel
®
Server System R2000WF Product Family System Integration and Service Guide
7.1

System Fan Replacement

System fans used in the Intel Server System R2000WF product family are hot-swappable.
CAUTION: To minimize possible performance degradation and other thermal related issues, system fan
replacement while the system is operational should be performed as quickly as possible.
System fans operate at very high speeds. Keep all tools and fingers away from all operational system fans
when swapping out a defective fan.
Components within an operational system can get very hot. Avoid touching any components within the
system while swapping out a defective system fan.
7.1.1

To remove a failed system fan

1.
Remove the system top cover (see Section 2.2.1)
2.
Locate the faulty system fan – The LED on the faulty fan should be illuminated
3.
Squeeze the two loop handles on the top side of the fan, and pull straight up until it clears the fan
module bracket.
7.1.2

To install a new system fan

1.
Locate the replacement fan (Intel product Code – FR2UFAN60HSW).
2.
Orient the fan so the arrow located on the top side of the fan points to the back of the system.
3.
Insert the fan into the fan module bracket.
4.
Push down until it is firmly seated into the server board connector.
5.
Re-install system top cover (see Section 2.2.2).

Figure 125. System Fan Removal

113

Advertisement

Table of Contents