Intel
®
Server System R2000WF Product Family System Integration and Service Guide
a)
Remove the six (6) screws from the top front edge of the drive bay
b) Pull the metal bracket straight out.
c)
Set aside the retention bracket and screws for re-installation at a later time.
2.
Remove Drive Bay Filler Panel(s)
The chassis includes a drive bay filler panel for each drive bay location that doesn't have a drive bay pre-
installed. Remove the filler panel for each 8 x 2.5" drive bay module to be installed.
a)
Carefully turn the chassis onto its side, exposing the bottom side of the chassis.
b) From the bottom of the chassis, remove the three (3) screw securing the given drive bay filler panel
(see Letter 'C').
c)
Carefully return the chassis to its original position.
d) Slide out the drive bay filler panel (see Letter 'D').
3.
Insert 8 x 2.5" Drive Bay Module
a)
Carefully unpack the 8 x 2.5" drive bay module from the accessory kit.
b) Slide the 8 x 2.5" drive bay module into the server chassis
Figure 8. Drive Bay Filler Panel Removal
Figure 9. 8 x 2.5" Drive Bay Module Installation
23