Operation
Parameter No.
Parameter
Pn002.0
Torque
command input
switching
Pn400
Torque control
scale
Note The default setting is 30 (x 0.1 V/rated torque).
D Limiting Analog Voltage with External Signals (Position, Speed, Internally-set
Speed Control)
• If Pn002.0 (torque command input switching) is set to 3, when PCL and NCL are ON, TREF (torque
command input) becomes the analog torque limit input terminal.
• Calculate the torque limit (%) as follows:
Absolute TREF voltage (V) / Pn400 (torque control scale) x 1000.
• Regardless of whether the voltage is positive or negative, both forward and reverse directions have
the same limits (taken as absolute values).
Parameter No.
Parameter name
Pn002.0
Torque command
input switching
Pn50b.2
Input signal selection
Pn50b.3
2
PCL signal selection
NCL signal selection
Pn400
Torque control scale
Note 1. If changing the default setting, set Pn50A.0 (input signal selection mode) to 1 (user-defined
settings).
Note 2. The default setting is 30 (x 0.1 V/rated torque).
Note 3. If using this function with internally-set speed control, set Pn50A.1 to 1 (user-defined set-
tings), and allocate the required input signals (PCL, NCL, SPD1, SPD2, RDIR, etc.).
4-5-11 Soft Start Function (Speed, Internally-set Speed
Control)
H Functions
• This function accelerates and decelerates the Servomotor in the set acceleration and deceleration
times.
• You can set the acceleration and deceleration independently of each other using the trapezoidal ac-
celeration and deceleration curve.
• The soft start processes REF (speed command input) or internally-set speed control switching to re-
duce shock during acceleration and deceleration.
• This function is effective for simple positioning and speed switching operations.
Note Do not use this function for a position controller with an acceleration/deceleration function.
name
Set Pn002.0 to 1. (Use TREF as analog torque
limit.)
Set TREF voltage when using rated torque. (See
note.)
Set Pn002.0 to 3 (use TREF as analog torque
limit when PCL and NCL are ON).
You must allocate PCL and NCL. (See note 1.)
Set TREF voltage for when the rated torque is
used. (See note 2.)
Explanation
Explanation
Chapter 4
Reference
4-4-4 Parameter
Details
Reference
4-4-4 Parameter
Details
4-4-3 Important
Parameters
4-4-4 Parameter
Details
4-93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-wtOmnuc w series

Table of Contents