System Design and Installation

3-2-3 Terminal Block Wiring

When wiring a Terminal Block, pay attention to wire sizes, grounding systems, and anti-
noise measures.
H Terminal Block Names and Functions
Terminal
Name
label
Main circuit
L1
power supply
p
pp y
i
input
t
L2
L3

Main circuit DC
output (positive)
Connection
1
terminals for DC
Reactor for
Reactor for
power supply
2
harmonic control
Main circuit DC
output (negative)
L1C
Control circuit
power supply
p
pp y
i
t
input
L2C
B1
External
regeneration
resistance
resistance
connection
B2
terminal
B3
U
Servomotor
connection
i
V
terminals
terminals
W
Frame ground
R88D-WTjH (30 to 400 W)
Single-phase 200/230 V AC (170 to 253 V), 50/60 Hz
g
p
R88D-WTjH (500 W to 6 kW)
Three-phase 200/230 V AC (170 to 253 V), 50/60 Hz
p
/
R88D-WTjHL (30 to 200 W)
Single-phase 100/115 V AC (85 to 127 V), 50/60 Hz
Do not connect anything to these terminals.
(Only the R88D-WT60H, R88D-WT75H, and R88D-WT150H have this termi-
nal.)
Normally short between 1 and 2.
When harmonic control measures are required, connect a DC Reactor be-
tween 1 and 2.
tween 1 and 2
(The R88D-WT60H, R88D-WT75H, and R88D-WT150H do not have these
terminals.)
Do not connect anything to these terminals.
R88D-WTjH
Single-phase 200/230 V AC (170 to 253 V), 50/60 Hz
g
p
R88D-WTjHL
Single-phase 100/115 V AC (85 to 127 V), 50/60 Hz
30 to 400 W: These terminals normally do not need to be connected. If there
is high regenerative energy, connect an External Regeneration Resistor be-
tween B1 and B2.
tween B1 and B2.
500 W to 5 kW: Normally short between B2 and B3. If there is high regenera-
tive energy, remove the short bar between B2 and B3 and connect an Exter-
nal Regeneration Resistor between B1 and B2.
nal Regeneration Resistor between B1 and B2
6 to 15 kW: Connect an External Regeneration Resistance Unit between B1
and B2.
Red
These are the output terminals to the Servomotor. Be careful to
wire them correctly.
i
h
White
Blue
Green/
Yellow
This is the ground terminal. Ground to a 100 Ω or less.
Function
(
),
(
),
/
(
),
p
l
Chapter 3
3-17