Mitsubishi MELSEC-Q/L Programming Manual page 790

Table of Contents

Advertisement

Category
Instruction
COM
CCOM
Application
instruction
FIFW
FIFR
FPOP
FINS
FDEL
788
Condition (Device)
When selecting I/O refresh
only
When selecting CC-Link
refresh only (master station
side)
When selecting CC-Link
refresh only (local station
side)
• When selecting
MELSECNET/H refresh
only (Control station side)
• When selecting CC-Link IE
Controller Network refresh
only (Control station side)
• When selecting
MELSECNET/H refresh
only (Normal station side)
• When selecting CC-Link IE
Controller Network refresh
only (Normal station side)
When selecting CC-Link IE
Field Network refresh only
(master station side)
When selecting CC-Link IE
Field Network refresh only
(local station side)
When selecting intelli auto
refresh only
When selecting I/O outside
the group only (Input only)
When selecting I/O outside
the group only (Output only)
When selecting I/O outside
the group only (Both I/O)
When selecting refresh of
multiple CPU high speed
transmission area only
When selecting
communication with external
devices only
Number of data points = 0
Number of data points = 96
Number of data points = 01
Number of data points = 96
Number of data points = 01
Number of data points = 96
Number of data points = 0
Number of data points = 96
Number of data points =01
Number of data points = 96
Processing Time (µs)
Q03
Q04/Q06
UD(E)CPU
UD(E)HCPU
Min.
Max.
Min.
Max.
12.800
29.100
12.400
28.600
16.000
39.500
15.500
39.100
16.100
39.500
15.500
39.100
34.700
70.400
34.400
69.800
34.700
70.400
34.400
69.800
17.000
38.800
16.600
38.000
17.000
38.800
16.600
38.000
12.800
33.200
12.800
33.200
7.900
21.100
7.700
20.700
16.900
44.800
16.500
44.200
22.600
52.600
22.400
52.600
13.000
33.800
12.700
33.200
7.250
18.800
7.100
18.500
3.700
5.300
3.200
4.600
3.800
4.400
3.300
3.800
4.300
5.000
3.800
4.400
33.500
35.500
24.800
25.700
4.300
5.900
3.800
5.300
4.300
5.900
3.700
5.400
4.800
5.900
3.700
5.300
4.300
5.900
3.700
5.300
4.900
6.500
4.200
5.800
34.200
35.900
25.400
25.900
Q10/Q13/Q20/
Q50/Q100
Q26UD(E)HCPU
UDEHCPU
Min.
Max.
Min.
12.400
28.600
12.400
15.500
39.100
15.500
15.500
39.100
15.500
34.400
69.800
34.400
34.400
69.800
34.400
16.600
38.000
16.600
16.600
38.000
16.600
12.800
33.200
12.800
7.700
20.700
7.700
16.500
44.200
16.500
22.400
52.600
22.400
12.700
33.200
12.700
7.100
18.500
7.100
3.200
4.600
3.200
3.300
3.800
3.300
3.800
4.400
3.800
24.800
25.700
24.800
3.800
5.300
3.800
3.700
5.400
3.700
3.700
5.300
3.700
3.700
5.300
3.700
4.200
5.800
4.200
25.400
25.900
25.400
Max.
28.600
39.100
39.100
69.800
69.800
38.000
38.000
33.200
20.700
44.200
52.600
33.200
18.500
4.600
3.800
4.400
25.700
5.300
5.400
5.300
5.300
5.800
25.900

Advertisement

Table of Contents
loading

Table of Contents