Mitsubishi MELSEC-Q/L Programming Manual page 306

Table of Contents

Advertisement

MTR
[Operation]
X010
X011
X012
X013 X014 X015 X016 X017 X018 X019 X01A X01B X01C X01D X01E X01F
X010
X011
X012
X013 X014 X015 X016 X017 X018 X019 X01A X01B X01C X01D X01E X01F
X010
X011
X012
X013 X014 X015 X016 X017 X018 X019 X01A X01B X01C X01D X01E X01F
Caution
(1) Note that the MTR instruction directly operates on actual input and output.
The output
that had been turned ON by the MTR instruction does not turn OFF when the MTR command turns OFF.
D1
Turn OFF the specified output
(2) The MTR instruction execution interval must be longer than the total of response time of input and output modules.
If the set interval is shorter than the value indicated above, an input cannot be read correctly.
If the scan time in a sequence program is short, select the constant scan and set the scan time longer than the total of
response time.
304
in the sequence program.
D1
3rd row
2nd row
1st row