Technical Data For Storage - Siemens SINAMICS G180 Installation And Operating Instructions Manual

Compact inverter units, cabinet systems, air-cooled and liquid-cooled cabinet units
Hide thumbs Also See for SINAMICS G180:
Table of Contents

Advertisement

Technical data
C.2 Technical data for storage
Environmental conditions for inverter transport
Humidity rating
Vibrations
C.2

Technical data for storage

The environmental conditions for storage according to EN 6180‑5‑1 for temperature, Class
1K4 and for relative humidity, Class 1K3 according to EN 60721‑3‑1 are specified as follows:
Environmental conditions for inverter storage
Atmospheric pressure
Ambient temperature
Humidity rating
170
Maximum relative humidity if the temperature of the inverter slowly increases by 40 K:
95 %
Maximum relative humidity if the device is brought immediately from -25 °C to +30 °C:
95 %
Maximum absolute humidity if the device is brought immediately from +70 °C to +15
°C: 60 g/m
3
Max. ≤ 1 g or ≤ 3.5 mm amplitude or according to Class 2M1 according to DIN IEC 721,
Part 3-2
860 mbar ... 1060 mbar, corresponds to max. 1000 m above sea level
- 25 °C ... + 55 °C
5 % ... 95 %, 1 g/m³ ... 29 g/m³
Installation and operating instructions Sinamics G180
Operating Instructions, 05/2013, 4BS0751-001

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents