Assignment Of The Analog Outputs; Input "Safe Halt" / Ptc Thermistor Inputs On Peripheral Board - Siemens SINAMICS G180 Installation And Operating Instructions Manual

Compact inverter units, cabinet systems, air-cooled and liquid-cooled cabinet units
Hide thumbs Also See for SINAMICS G180:
Table of Contents

Advertisement

Operation
8.8 Examples / Applications
8.8.1.10

Assignment of the analog outputs

● Isolated terminal ‑X2:62, 63:
● Isolated terminal ‑X2:60, 61:
● Terminal ‑X2:64, 67:
8.8.1.11

Input "Safe halt" / PTC thermistor inputs on peripheral board

Detailed information
Detailed information can be found in the section "Peripheral boards 1 to 4" (Page 136).
124
An output signal of 4 mA to 20 mA is present here. This corresponds to a motor current
from zero up to a unit-dependent value.
This output provides a speed signal. A value from 4 mA to 20 mA is the default. This
corresponds to a motor speed from 0 to 1500 rpm.
In the case of the "peripheral board 1 ... 4" option, the torque and the power are available
at these terminals. A value from 4 mA to 20 mA is the default. The corresponding
countervalue is output-dependent and is stored in the software "IMS".
Installation and operating instructions Sinamics G180
Operating Instructions, 05/2013, 4BS0751-001