4. Replug the connector.
5. Reassemble in the inverse order.
6.7.4.2

Preparing compact devices with size up to 225 mm

This instruction is applicable for compact units up to a size of 225 mm with the identifier
2T..‑07400‑015 or 2T..‑07500‑037.
Procedure
1. Turn the four fixing screws of the gray cover through 90° and lift up the cover.
2. Unscrew the blue cover at the screw above –X25 and lift up the cover.
3. Turn the four fixing screws of the swivel section by 90°, swivel the swivel section to the right
4. Replug the connector.
5. Reassemble in the inverse order.
Compact device W=165, connector for external
control voltage
6.7.4.3

Preparing compact devices with frame size K4 with 400 V or 500 V

This instruction applies to compact units with the frame size K4 with L x W 775 × 350 mm and
400 V or 500 V rated voltage.
Installation and operating instructions Sinamics G180
Operating Instructions, 05/2013, 4BS0751-001
and clip the swivel section to the side panel according to the picture below.
6.7 Connection of external control voltage
Compact device W=225, connector for external
control voltage